DESIGN CHARACTERISTICS
A high-quality, reliable, and compact power unit.
Compact design ensuring easy handling and maintenance.
Each generator set undergoes a comprehensive testing program, including full-load tests, performance verification, and safety shutdown control.
ENGINE
Heavy-duty RICARDO diesel engine, 4-stroke, water-cooled, 1500 rpm, turbocharged or naturally aspirated with after-cooling.
-
Direct fuel injection system.
-
12V DC starter motor and charging alternator.
-
Replaceable fuel, oil, and air filters (dry type).
-
Cooling radiator and fan.
-
12V lead-acid starting battery including frame and cables.
-
Flexible fuel hoses and oil sump drain valve.
-
Industrial-grade exhaust silencer with steel bellows.
-
Jacket water heater (for automatic models).
ALTERNATOR
-
Brushless, single-bearing, 4-pole system.
-
Insulation class H, protection class IP21.
-
Self-excited and self-regulated.
-
Epoxy resin impregnation for tropical environments.
-
Automatic Voltage Regulator (AVR) included.
BASE FRAME
-
The complete generator set is mounted as a single unit on a reinforced steel base frame.
-
Anti-vibration pads are installed between the engine, alternator, and base frame.
-
The base frame integrates the fuel tank.
-
The unit can be lifted or towed safely using the frame.
-
Lifting eyes for crane handling.
-
Analog fuel level gauge and drain plug on the fuel tank.
CANOPY
-
All canopy parts are modular and assembled without welding.
-
Access doors on each side.
-
All metal parts are electrostatically painted.
-
Polyester powder coating protects the silencer from corrosion.
-
Thermally insulated exhaust system.
-
Emergency stop button located externally.
-
Easy to lift, transport, and service.
PERFORMANCE RATING
Standby Power:
Maximum available power during variable load operation under defined conditions. The generator can operate for up to 500 hours per year at 70% average load. Overload is not permitted.
Prime Power:
Maximum power available for continuous operation with variable load. The average load should not exceed 70%.
The generator can be overloaded by 10% for 1 hour every 12 hours of operation.
All data and ratings comply with ISO 8528, ISO 3046, NEMA MG1.22, IEC 60034-1, BS 4999/5000, and VDE 0530.
Manufactured under ISO 9001 quality management system and CE-certified.
TECHNICAL SPECIFICATIONS
| Parameter | Value |
|---|---|
| Fuel Type | Diesel |
| Configuration | Soundproof Canopy |
| Maximum Power (kW) | 44 kW |
| Rated Power (kW) | 40 kW |
| Starting System | Manual / Electric / Automatic |
| Alternator Type |