Model 6000SP
Type: Gasoline generator
Phase Type: Single-phase
Maximum Power: 5.4 kW
Rated Power: 5.0 kW
Rated Voltage: 230 V
Starting System: Manual start
Continuous Operation Time: 14 hours
Fuel Consumption (at 75% load): 1.8 L/h
Automatic Voltage Regulator (AVR) — included as standard
Sockets: 1 × 16A 230V, 1 × 32A 230V
DC Output: 12V
Portable Single-Phase Gasoline Generator 6000SP 230V – 5.4 kW
from the Italian manufacturer CGM
CGM gasoline generators operating at 3000 rpm are lightweight and compact, equipped with an independent fuel tank and a trolley for easy mobility.
Thanks to its compact size, ease of operation, and low weight, the 6000SP power unit is ideal for use as a mobile power generator.
| Parameter | Specification |
|---|---|
| Type | Gasoline generator |
| Maximum Power | 5.4 kW |
| Rated Power | 5.0 kW |
| Current | 29.3 A |
| Number of Phases | 1 |
| Frequency | 50 Hz |
| Rated Voltage | 230 V |
| Parameter | Specification |
|---|---|
| Model | CGM 14HP |
| Engine Type | 4-stroke, single-cylinder, OHV |
| Cooling | Air-cooled |
| Starting System | Manual start |
| Winding Material | Copper |
| Displacement | 420 cc |
| Fuel Tank Capacity | 25 L |
| Power | 14 / 10.4 HP / kW |
| Speed | 3000 rpm |
| Fuel Type | Unleaded gasoline |
| Fuel Consumption | 1.8 L/h (at 75% load) |
| Parameter | Specification |
|---|---|
| Socket Type | 1 × 16A 230V, 1 × 32A 230V |
| Installation Type | Mobile (on wheels) |
| Application | For garage, cottage, home, or summer house |
| Features | 32A power socket |
| Design | Open type |
| Parameter | Specification |
|---|---|
| Dimensions (L×W×H) | 717 × 545 × 592 mm |
| Weight | 67 kg |
| Class | Professional |
| Noise Level | 70 dB (at 7 m) |
| Country of Origin | Italy |
Additional Features:
Automatic Voltage Regulator (AVR)
Overload protection
Low oil level protection
Fuel level sensor
Digital multifunction display (voltmeter, frequency meter, hour meter)
| Model | 230V (kVA max / kW max) | 400V (kVA max / kW max) | Engine | Cylinders | Power (HP / kW) | Displacement (cc) | Fuel Consumption (L/h) | Fuel Tank (L) | Weight (kg) | Dimensions (mm) |
|------------|-----------------------------|-----------------------------|-------------|----------------|---------------------|-----------------------|-----------------------------|-------------------|------------------|
| 3000SP | 3 / 2.7 | — | CGM 7HP | 1 | 7 / 5.2 | 208 | 1.2 | 15 | 45 | 617 × 475 × 467 H |
| 6000SP | 6 / 5.4 | — | CGM 14HP | 1 | 14 / 10.4 | 420 | 1.8 | 25 | 67 | 717 × 545 × 592 H |
| DUAL20000SP | 20.7 / 16.5 | 20.7 / 16.5 | OHV1000 | 2 | 32 / 23.8 | 999 | 9.8 | 65 | 255 | 970 × 680 × 955 H |
| 9000SPTA | 9 / 7.2 | — | CGM 16HP | 1 | 16 / 11.7 | 460 | 2.1 | 25 | 87 | 725 × 600 × 620 H |
1. Homes, Shops, and Large-Scale Distribution
Reliable power supply solutions for residential buildings, retail stores, and distribution facilities.
2. Construction
A generator is one of the most frequently used tools on construction sites or in industrial environments that demand specific characteristics such as reliability and power.
The generator set is a fundamental component for workshops, construction companies, and infrastructure operations.
3. Telecommunications and Various Supply Systems
A continuous power supply is essential for mobile communication installations.
The operation of mobile phones and wireless devices requires low but uninterrupted power, therefore high-quality generators specifically designed for telecom or supply systems are indispensable.
4. Hospitals
The reliability and immediacy of power delivery for hospital generator sets are of vital importance.
For this reason, it is necessary to install high-quality generator systems capable of meeting the needs of hospital departments and medical facilities.
5. Factories and Industry
Generator sets intended to supply power to factories and production facilities are characterized by durable components and high output power.
They are suitable for various industrial purposes and can be customized to meet specific operational requirements.
6. Sports Centers, Fairs, and Large Events
Selecting the right generator sets to support both large and small events is crucial for maintaining the required electrical load.
Generators used for concerts, fairs, sports facilities, and major events are typically soundproof, ensuring uninterrupted operation and the overall success of the event.
7. Tourism Sector
Hotels, B&Bs, and other businesses in the tourism industry must compensate for any power shortages to provide their guests with the best quality of service.
For this purpose, there are dedicated generator sets that are better suited to meet the specific energy requirements of the hospitality sector.
8. Automotive Applications
These are adaptable-size generators designed for installation and transportation on vehicles.
They provide power whenever and wherever needed.
Automotive generator sets can be installed on vans, trucks, or tractor trailers, depending on the unit’s size and intended use.